Press the [Move Adjust Pos.] button.
The camera axis moves to adjustment position (right side of the mask holder).
Press the Emergency Stop button.
Set the adjustment tool on the machine.
Open the machine front door and set the adjustment tool on the plate part in front of the mask holder.
Set the tool on the front plate part.
Check the image taken by the mask camera on the [Move Axis] screen.
Adjust the head unit position manually or by moving axis and make sure that the light gray portion of the
lighting axis is projected on whole angle of view.
Check for safety in and around the machine so that the head unit can be moved
safely.
Release the Emergency Stop button.
Press the [Execute] button.
Use masking tape to
fix the tool in place.
SI1906002E-001=YSP10 installation and adjustment procedures
83/120
For Service Engineers
Service Information
Set the tool to make the tool's light
gray portion is in full view of the mask
camera.