SL2100
Level:
SA
Description
Use Program 12-08 : Night Mode Service Range to define the changing range of toggle key for each
Program
Day/Night Mode.
12
Input Data
Item
No.
01
Toggle Between Night
Modes
02
Lamp setting of tog-
gle key
Example :
When Program 12-08-01 is set to 3 and the Mode Key is pressed, the following modes are switched :
• Press once = Night
• Press twice = Mid-night
• Press third = Day
• Default = 2
Conditions
None
Feature Cross Reference
• Night Service
2-104
Program 12 : Night Mode Setup
Night Mode Group Number
Item
Input Data
2 ~ 8
0 = Off
1 = On

12-08 : Night Mode Service Range

Description
When a Night Mode Key (PRG 15-07 key
09) is assigned as a toggle key (PRG
20-01-17), this data determines how many
night modes a user toggles through when
the Night Mode key is pressed. Each press
of the Night Mode key toggles to the next
mode.
Whether the Lamp of toggle key sets on or
off.
Program 12 : Night Mode Setup
ISSUE 2.0
1 ~ 4
Default