Push Notification Service Basic Setup - NEC SL2100 Programming Manual

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

ISSUE 2.0
Program 10 : System Configuration Setup

10-76 : Push Notification Service Basic Setup

Level:
IN
(This Program is available for V2.00 or higher)
Description
Use Program 10-76: Push Notification Service Basic Setup to enable Push Proxy Server access
for PUSH Notification to the VoIP Application.
In Program 24-02-15 change the initial value to 8 sec when using the Push Notification service.
Input Data
Item
Item
No.
01
Domain Name
02
Access Key
03
Server Certificate
04
HTTPS proxy server
address
05
HTTPS proxy server
port
Item No.
01
02
Conditions
None
Feature Cross Reference
• IP Single Line Telephone (SIP) - PUSH Notification
Programming Manual
Input Data
Maximum 128 charac-
Set Domain Name of Push Proxy Server.
ters
Read Only
Maximum 32 characters
Enter Server Certificate file name.
0.0.0.0 ~
Set HTTPS Proxy Server IP Address.
126.255.255.254
128.0.0.1 ~
191.255.255.254
192.0.0.1 ~
223.255.255.254
1 ~ 65535
Set HTTPS Proxy Server port number.
Table 2-1 Default
usa01.nec-pushproxy.com
A2Hi123s>Y=RBx4u5DIt7wO9?70M<2@JMsCD8QErFX:N96GyDBLsK6NsJZ;P2V63
Description
In SL2100 Ver 2.00, this program is on-
ly enter the Server Certificate file name
"AmazonRootC1.pem" which is inclu-
ded in the system.
Default
SL2100
Program
10
Default
Refer below
Refer below
-
0.0.0.0
8080
2-63

Hide quick links:

Advertisement

Table of Contents
loading