Etu Setup - NEC SL2100 Programming Manual

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

ISSUE 2.0
Program 10 : System Configuration Setup
Level:
IN
Description
Use Program 10-03 : ETU Setup to setup and confirm the Basic Configuration data for each board.
When changing a defined terminal type, first set the type to 0 and then plug the new device in to have
the system automatically define it or you may have to reseat the board.
The items highlighted in gray are read only and cannot be changed.
Input Data
Slot No.
For HBI PKG Setup
Physical Port Number
Item No.
01
Terminal Type
02
Logical Port Number
03
Transmit Gain level for SLT
04
Receive Gain level for SLT
05
Select port type
06
Multi-Line Telephone Line
For ESI PKG Setup
Physical Port Number
Programming Manual
Item
0 = No Setting
1 = Multi-Line Telephone
2 = SLT
8 = Door Phone
10 = DSS Console
3 ~ 7, 9, 11, 12 = Not Used
[Terminal Type = 0] : 0
[Terminal Type = 1] : 1 ~ 128
[Terminal Type = 2] : 1 ~ 128
[Terminal Type = 8] : 1 ~ 2
[Terminal Type = 10] : 1 ~ 12
1 ~ 57
(- 15.5 ~ + 12.5 dB)
1 ~ 57
(- 15.5 ~ + 12.5 dB)
0 = Hybrid Port
1 = Door Phone
0 = None
1 = 12 Line
2 = 24 Line

10-03 : ETU Setup

1 ~ 12
1 ~ 8
Input Data
1 ~ 8
SL2100
Program
10
Default
2
0
32
32
0
0
2-9