Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate
an alarm as Major or Minor. This program also assigns whether or not the alarm information is
reported to the predefined destination.
Input Data
Alarm Number
Item
Item
No.
01
Alarm Type
02
Report
Item
Alarm
No.01
Name
No.
de-
fault
1
PKG Initial-
2
ize Error
Programming Manual
Program 90 : Maintenance Program
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0 = Not Report (No autodial)
1 = Report (autodial)

Table 2-22 Description of Alarm

Item
Content of
No.02
alarm
de-
< generation
fault
timing >
0
It failed in the
1.
initialization of
the package.
The package
2.
was not able to
be started nor-
mally.
<The package
starts >
3.

90-10 : System Alarm Setup

1 ~ 200
Input Data
Cause
Measures
The unit
1.
Please insert
doesn't insert
the unit firmly.
firmly.
2.
Please insert
The unit is tak-
the unit firmly.
en out once,
3.
Please delete
and it doesn't
slot informa-
insert it again
tion with
firmly.
PRG90-05 and
Because infor-
insert the unit
mation on the
again.
unit that had
been mounted
before re-
mains, a unit
different from
the information
doesn't do the
initialization
completion.
SL2100
Program
90
Default
*1
*1
Alarm
Recovery
Status
It doesn't re-
ERR
cover it au-
REC
tomatically.
When the
unit is rec-
ognized
again, the
error is re-
covered.