System Alarm Report Setup - NEC SL2100 Programming Manual

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

ISSUE 2.0
Level:
IN
Description
Use Program 90-11 : System Alarm Report Setup to define the details of the system alarm report.
Input Data
Item
Item
No.
02
Report Method
06
SMTP Host Name Up to 255 Characters
07
SMTP Host Port
Number
08
To E-mail Ad-
dress
09
Reply Address
10
From Address
13
Customer Name
14
Change SMTP
Client
15
DIMLOG Notifica-
tion
Conditions
None
Programming Manual
Program 90 : Maintenance Program

90-11 : System Alarm Report Setup

Input Data
0 = No Report
When alarm reports are e-mailed,
1 = E-mail Address
set this option to 1. E-mail address
set in 90-11-08.
When alarm reports are e-mailed,
set the SMTP name (ex : smtp.your-
isp.com). Contact your ISP (internet
service provider) for the correct en-
try if needed.
0 ~ 65535
When alarm reports are e-mailed,
set the SMTP host port number.
Contact your ISP (internet service
provider) for the correct entry if nee-
ded.
Up to 255 Characters
When alarm reports are e-mailed,
set this e-mail address to which the
report should be sent.
Up to 255 Characters
When alarm reports are e-mailed,
set the e-mail address where replies
should be e-mailed.
Up to 255 Characters
When alarm reports are e-mailed,
set this e-mail address for the sta-
tion sending the report.
Up to 255 Characters
When alarm reports are e-mailed,
enter a name to identify the particu-
lar system.
0 = No
When enabled the system uses the
1 = Yes
programs in 47-18-xx for email serv-
er integration.
0 = No
When enabled, the system will send
1 = Yes
an email notification when a system
fault occurs and DIMLast/DIMDump
files are generated. If PRG 90-11-14
is also enabled the logs files will be
attached to the email.
Description
Default
No Setting
No Setting
No Setting
No Setting
No Setting
SL2100
Program
90
Related
Program
0
25
0
90-11-08
90-25-01
47-18
47-19
90-11
0
90-11-14
2-593