NEC SL2100 Programming Manual page 543

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

ISSUE 2.0
Program 82 : Basic Hardware Setup for
Level:
MF
Description
Use Program 82-04 : SLIU Initial Data Setup to set the basic data of the SLT.
Input Data
Item
Item
No.
01
Companding Method Type
02
Ringing Frequency
03
Minimum Break Time
04
Maximum Break Time
05
Minimum Make Time
06
Maximum Make Time
07
Minimum Hook Flash Time
08
Maximum Hook Flash Time
09
Minimum Ground Flash Time
10
Minimum Off-Hook Time
11
No Detection Time after Off-Hook
12
No Detection Time after Pulse Dial
Detection
13
Loop Disconnect Time, Reversal
Time
14
Ring, Message Wait Period Time
15
Door Phone button ON time
16
Door Phone button OFF time
Conditions
None
Feature Cross Reference
None
Programming Manual
82-04 : SLIU Initial Data Setup
Input Data
0 = μ-law
1 = A-law
0 = 25 Hz
1 = 20 Hz
2 = 16 Hz
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (10 ms ~ 2550 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5ms ~ 1275 ms)
1 ~ 255 (5ms ~ 1275 ms)
SL2100
Extension
Default
0
1 (20 Hz)
2 (10 ms)
20 (100 ms)
2 (10 ms)
20 (100 ms)
21 (105 ms)
132 (660 ms)
21 (105 ms)
21 (105 ms)
60 (300 ms)
70 (350 ms)
60 (600 ms)
150 (750 ms)
50 (250 ms)
20 (100 ms)
2-519