Removing the Gearbox Assembly (continued)
Greensmaster
®
eFlex 1021
20248SL Rev C
1. Ensure that the cutting-unit-drive lever is in the D
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
the Operator's Manual.
2. Disconnect the battery; refer to
Battery Pack (page
3. Remove the cutting unit from the machine and place it on a level work
surface; refer to Operator's Manual.
4. Remove the groomer reel assembly; refer to
(page
8–19).
5. Remove the cap from the lip of the groomer drive gearbox cover
6. Tip up the cutting unit to access the bottom of the reel to remove the drive
shaft assembly.
7. Insert a long-handled pry bar (3/8 x 12 inch with screwdriver handle
recommended) through the bottom of the cutting unit. The pry bar should
pass between the bottom of the reel shaft and the backs of the reel blades so
that the reel will not move.
To avoid grinding the reel, do not contact the cutting edge of any
blade with the pry bar as this may damage the cutting edge and/or
cause a high blade.
8. Move the pry bar against the weld side of the reel support plate closest to the
groomer gearbox, and lift the pry bar until it contacts the front roller.
FF
Disconnecting and Connecting the Lithium
5–3).
IMPORTANT
Page 8–5
Universal Groomer (Optional): Service and Repairs
position, park the
ISENGAGE
, and remove the key; refer to
Removing the Groomer Reel
(Figure
121).