Download Print this page

Dell PowerVault 124T DLT VS160 User Manual page 4

Autoloader
Hide thumbs Also See for PowerVault 124T DLT VS160:

Advertisement

Installing the Autoloader: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
SCSI Bus Requirements
You must connect the Dell PowerVault 124T DLT VS160 autoloader to one of the following SCSI bus types:
Ultra 160 SCSI, Low-voltage Differential (LVD)
Ultra 320 SCSI, Low-voltage Differential (LVD)
Single-ended (SE) SCSI bus
NOTE: The Dell PowerVault 124T DLT VS160 autoloader is not compatible with a High-voltage Differential (HVD) SCSI
bus.
Your SCSI host adapter card must also support the SCSI bus type used to connect the autoloader. If you use a LVD SCSI bus,
use a host adapter card with a connection for a high-density (HD) 68-pin cable.
NOTE: If you use an SE SCSI bus, the tape drive's performance is limited to the maximum data transfer speed of the
bus.
NOTE: The maximum number of autoloaders supported per SCSI bus is two.
NOTE: The autoloader may not work with multiple SCSI LUNS when attached to a redundant array of independent disks
(RAID) controller. The autoloader is not recommended for use with a RAID controller. If this problem occurs, it is
recommended that the autoloader be attached to a separate SCSI bus controller on the server.
Accessories
The following accessories are shipped with the Dell PowerVault 124T DLT VS160 autoloader:
Getting Started Guide
SCSI host cable
SCSI terminator
Hardware to rack mount the autoloader (autoloader rails are included, rack rails are optional)
One magazine blank
Power cable
Documentation CD containing all of the documentation in Adobe® Portable Document Format (PDF) and supplied device
drivers
Bar code labels
TORX L-key drivers (T8 and T10)
Emergency Magazine Removal Tool
Choosing a Location
Choose a location that meets the following criteria (see
NOTICE: Do not place the autoloader on its side or upside down. Do not stack anything on top of the autoloader.
Rack
Standard 19-inch rack with 2U (3.5 in.) of clearance.
Requirements
Room
10–35°C (50–95°F)
Temperature
Power Source AC power voltage: 100–127 VAC; 200–240 VAC
Line frequency: 50–60 Hz
file:///T|/htdocs/stor-sys/124T/en/124tvs16/install.html[12/5/2012 10:25:55 AM]
NOTE: Locate the AC outlet near the autoloader. The AC power cable is the product's main AC
disconnect device and must be easily accessible at all times.