Troubleshooting: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
Autoloader Operating System Failure Types
01
Resource Deleted
02
Pool Error
03
Pointer Error
04
Wait Error
05
Size Error
06
Group Error
07
No Event Timeout
08
Option Error
09
Queue Error
0A
Queue Empty
0B
Queue Full
0C
Semaphore Error
0D
Semaphore Timeout
0E
Thread Error
0F
Priority Error
10
Start Error
11
Delete Error
12
Resume Error
13
Caller Error
14
Suspend Error
15
Timer Error
16
Tick Error
17
Activate Error
18
Threshold Error
19
Suspend Lifted
1A
Block Pool Error
1B
Queue Function Failed
1C
Semaphore Function Failed
1D
Timer Function Failed
1F
Thread Function Failed
20
Command Started
21
System Failure
22
System Busy
23
System Timeout
24
Software Error
25
Hardware Error
file:///T|/htdocs/stor-sys/124T/en/124tvs16/trouble.htm[12/5/2012 10:26:08 AM]
Errors 01-25 indicate that an unexpected event has occurred within the
autoloader internal operating system. The autoloader internal operating system is
called ThreadX, and some error messages may be preceded by a 'TX' notation.
For any of these events:
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
Check
support.dell.com
If all previous steps fail, contact support.dell.com.
for PowerVault 124T firmware updates.