0000000000001000
Drive TAflag[53]
Tape System Area
Read Failure
TapeAlert Log Entry:
0000000000000800
Drive TAflag[54] No
Start Of Data
TapeAlert Log Entry:
0000000000000400
Drive TAflag[55]
Loading Failure
TapeAlert Log Entry:
0000000000000200
Drive TAflag[56]
Unrecoverable
Unload Failure
TapeAlert Log Entry:
0000000000000100
Drive TAflag[57]
Automation Interface
Failure
TapeAlert Log Entry:
0000000000000080
Drive TAflag[58]
Firmware Failure
TapeAlert Log Entry:
0000000000000040
Drive TAflag[59]
WORM Medium -
Integrity Check
Failed
TapeAlert Log Entry:
0000000000000020
Drive TAflag[60]
WORM Medium -
Overwrite Attempted
TapeAlert Log Entry:
0000000000000010
file:///T|/htdocs/stor-sys/124T/en/124tvs16/trouble.htm[12/5/2012 10:26:08 AM]
The tape system area could not be
read successfully at load time.
The start of data could not be found
on the tape.
The operation has failed because the
media cannot be loaded and
threaded.
The operation has failed because the
medium cannot be unloaded.
The tape drive has a problem with
the automation interface.
The tape drive has reset itself due to
a detected firmware fault.
The tape drive has detected an
inconsistency during the WORM
medium integrity checks.
An attempt had been made to
overwrite user data on WORM
medium.
Read errors while
reading the system area
on load
Tape damaged, bulk
erased, or incorrect
format.
The drive is unable to
load the media and
thread the tape.
The drive is unable to
unload the medium.
The drive has identified
an interface fault.
Firmware issue
encountered.
WORM cartridge may
have been tampered
with.
The application software
does not recognize the
medium as WORM.
Copy data to another tape
cartridge.
Check that you are using
the correct format tape.
Discard the tape or return
the tape to your supplier.
Remove the cartridge, inspect it
as specified in the product
manual, and retry the operation.
Remove the cartridge if possible,
inspect it as specified in the
product manual, and retry the
operation.
Check the power to the
automation system.
Check the cables and cable
connections.
Replace WORM medium.
If a WORM medium was
used inadvertently, replace
it with a normal data
medium.
If a WORM medium was
used intentionally:
- check that the software

Advertisement

loading