Technical Specifications: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
Interface
LVD ultra wide SCSI-2, 16-bit wide, 68-pin HD connector
Initialize element
90 seconds (typical)
status
Typical cycle time
< 40 seconds. One cycle consists of moving a cartridge from the tape drive to a magazine slot, selecting
another magazine slot, and then moving the cartridge back to the tape drive. It does not include the
time that the tape drive takes to unload or load/calibrate.
Average load time
VS1 = 120 seconds (to BOT for previously written tape)
(after placing
cartridge in drive)
Average unload
VS1 = 25 seconds (from BOT)
time (from BOT)
Autoloader Environmental Specifications
Characteristic
Temperature Range (Dry Bulb)
Operating
Nonoperating
Temperature Variation
Operating
Nonoperating
Humidity
Operating
Nonoperating
Gradient
Wet Bulb
Operating
file:///T|/htdocs/stor-sys/124T/en/124tvs16/specs.html[12/5/2012 10:26:14 AM]
Specification
+10º to +35ºC
–40º to +65ºC
10ºC per hour
20ºC per hour
20% to 80% noncondensing
10% to 90% noncondensing
10% per hour without condensation
26ºC maximum