Download Print this page

Dell PowerVault 124T DLT VS160 User Manual page 55

Autoloader
Hide thumbs Also See for PowerVault 124T DLT VS160:

Advertisement

Troubleshooting: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
7D
SCSI Error During Write
Buffer Command
7E
Uncompressed EDC Failure
7F
Image Processing Ended
Early
SCSI Server Task Error Types
80
Unexpected Response or
Data Received
81
Drive Send Failed
Servo Elevator Hardware Error Types
92
Elevator Flag Bad
93
Elevator Sensor Bad
97
Elevator Calibration Lost
98
Elevator Calibration
Jammed
99
Elevator Lost
9B
Elevator Position Error
Picker/Magazine Servo Error Types
A0
Servo Error
A1
Reserved Error Code
A2
Servo Timeout Error
A3
Position Error
A4
Servo Not Calibrated
A5
Source Element Empty
file:///T|/htdocs/stor-sys/124T/en/124tvs16/trouble.htm[12/5/2012 10:26:08 AM]
Verify the host backup application and device driver are at the latest
supported revision at support.dell.com.
Check host adapter and SCSI cables and terminator.
Power cycle the autoloader and retry the operation.
If all previous steps fail, contact support.dell.com.
Power cycle the autoloader
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
Check
support.dell.com
If all previous steps fail, contact support.dell.com.
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Also execute the Recommended Actions for "Open Front" (4B) error type.
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
Check
support.dell.com
If all previous steps fail, contact support.dell.com.
Verify that the expected source really does not have a cartridge.
Power cycle the autoloader.
Run the Random Moves test from either the Remote Management Unit
(RMU) or the Operator Control Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges
present within the autoloader.
If the source is a slot within a magazine, check if the spring loaded
cartridge present flag moves freely when the cartridge is manually inserted
into the magazine.
If the error continues, contact support.dell.com.
for PowerVault 124T firmware updates.
for PowerVault 124T firmware updates.

Advertisement

loading