Procedure For Ipx-U And Imx-U Systems - NEC NEAX 2400 IPX Manual

Fusion network
Hide thumbs Also See for NEAX 2400 IPX:
Table of Contents

Advertisement

When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, be sure to use at least two
HUB cards as separate 10 BASE-T connection terminals. Use one HUB for the internal LANI
(LANI-A: in Slot 00 of each CPR), and use the other for the external LANI (LANI-B in Slot 03 of
each CPR).
2. When the HUB is in a dual configuration, connect the 10 BASE-T cross cable between the HUB
cards. Use the following cables, which are provided by the user.
UTP CTG5 CRS CA-F:When the HUB and HUB are in the same PIM
UTP CTG5 CRS CA-O:When the HUB and HUB are in different PIMs but in the same IMG
UTP CTG5 CRS CA-X:When the HUB and HUB are in different IMG stacks
When using more than two HUB cards, also connect the cross cable(s) for the remaining HUB
card(s), except the HUB for the MAT connection.
This step is not necessary when your system uses dual LANIs for CPU#0/CPU#1 and FCH is also
in a dual configuration.
3. Connect the 10 BASE-T straight cable(s) between the HUB and FCH (PA-FCHA) cards. Use the
following cable, which must be provided by the user.
UTP CTG5 ST CA-F:When the HUB and FCH are in the same PIM
UTP CTG5 ST CA-O:When the HUB and FCH are in different PIMs but in the same IMG
UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks
When FCH is in a dual configuration, connect FCH#0 to the HUB#0 side and FCH#1 to the HUB#1
side.
4.3.5

Procedure for IPX-U and IMX-U Systems

When your system is the IPX-U or IMX-U type (configured to a maximum of 4 Local Nodes + 1ISW),
the procedure for the 10 BASE-T connection is as follows. Because this system already has a Fusion
link via the HUB (PA-M96) cards, this section gives details related only to the connection between the
HUB and FCH (PA-FCHA) cards.
1. Refer to the NEAX2400 IPX Installation Manual (IMX-U Type) or the NEAX2400 IMX
Installation Manual (IMX-U Type) to make sure that the necessary 10 BASE-T (both straight and
cross) connections between the ISW and each LN (Local Node) are all securely provided.
2. Connect the 10 BASE-T straight cable(s) between the HUB (PA-M96) and FCH (PA-FCHA) cards.
Use the following cable, which must be provided by the user.
UTP CTG5 ST CA-F:When the HUB and FCH are in the same PIM
UTP CTG5 ST CA-O:When the HUB and FCH are in different PIMs but in the same IMG
UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks but in the same LN
UTP CTG5 ST CA-A0:When the HUB and FCH are in different LNs
NDA-24299
INSTALLATION
Connecting Cables
CHAPTER 4
Page 49
Revision 1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents