Connecting 10 Base-T Cables; Figure 4-11 Overall 10 Base-T Connections - NEC NEAX 2400 IPX Manual

Fusion network
Hide thumbs Also See for NEAX 2400 IPX:
Table of Contents

Advertisement

INSTALLATION
Connecting Cables

4.2 Connecting 10 BASE-T Cables

Figure 4-11
shows sample cable connections, where HUB (PA-M96) cards are provided in a dual
configuration and the FCH (PA-FCHA) card is located in PIM 1 (1-IMG system/IMG0). When HUB cards
are provided in a dual configuration, the two HUB cards must be connected on each front edge connector
with a 10 BASE-T cross cable. However, when dual LANIs (LANI-A and LANI-B) are used for each CPU,
the cross cable connection between HUBs for FCH#0 and #1 is not necessary.
The Ethernet cables shown in the examples in this section are NOT available from NEC. The customer must
Note:
provide these cables, depending on the system configuration. See
Cables."
REAR VIEW
: 10 BASE-T cable (for Fusion Link)
Note:
When connecting the MAT using a HUB card, be sure to use a dedicated HUB for the MAT.
CHAPTER 4
Page 46
Revision 1.0
FCH (PA-FCHA)
MAT
to MAT

Figure 4-11 Overall 10 BASE-T Connections

DTI
10 BASE T cable
(cross)
LANI (PZ-PC19)
Note
: 10 BASE-T cable (for MAT)
NDA-24299