DATA PROGRAMMING
Assignment of System Data
STEP 4: ASYDL and ASYDN
Assign other system data using the ASYDL/ASYDN command.
When Timing Start is used, assign the following data.
Index 161
b6 : 0/1=-/Timing Start using "#" code
b7 : 0/1=-/Timing Start using "*" code
Index 170
b4 : 0/1=Timing Start out of Service/Timing Start in Service
Index 640
Fusion Point Code (FPC) of node providing ATTCON
Index 704~735 (ASYDL)
FPC of the node to which ATTCON transfers the Day/Night changeover information.
Assign FPC of a terminating node for House Phone, Off-Hook Alarm and Ring Down (IC) calls from PSTN.
Day/Night information is transferred from the terminating node.
When Timing Start is in service, Called Sub Address for ISDN Network cannot be dialed.
Note 1:
Note 2:
This data is necessary at each node. Assign the self-FPC at the terminating node.
Note 3:
This data is necessary at the node providing ATTCON.
Index 800
For ASYDL
For ASYDN
CHAPTER 5
Page 66
Revision 1.0
b0 : 0/1 = ALGNL, ALGSL on a UGN (TN) basis/-
b1 : 0/1 = ASPAL on a TN basis/-
b2 : 0/1 = ANPDL on a TN basis/-
b4 : 0/1 = AFRSL, ASTPL, AUNEL on a TN basis/-
b5 : 0/1 = ASTPL on a TN basis/-
b7 : 0/1 = AAEDL on a TN basis/-
b0 : 0/1 = ALGNN, ALGSN on a UGN (TN) basis/-
b1 : 0/1 = ASPAN on a TN basis/-
b2 : 0/1 = ANPDN on a TN basis/-
b4 : 0/1 = AFRSN, ASTPN on a TN basis/-
b5 : 0/1 = ASTPN on a TN basis/-
b6 : 0/1 = ARSCN on a TN basis/-
b7 : 0/1 = AAEDN on a TN basis/-