STEP 2: ACTK
Assign the connection trunk data of both B-channel and D-channel using the ACTK command.
Assign the Connection Equipment Number (C_LENS) referring to
The ACTK command display should look similar to
ACTK (Assignment of Connection Trunk Data for Local Data Memory)
C_RT
C_TK
10
1
C_LENS
000010
WRT?
Y
The mounting location of the FCH, DTI cards can be classified into the following two types:
Regular Density Slot (16-port slot) -See
High Density Slot (32-port slot) -See
6.1.1
When FCH is mounted in a Extended Density Slot
If the FCH is to be mounted in the Extended Density Slot, the connection trunk should be assigned as
shown in the figures below. If the card's mounting location is in any of the Slot Nos. 04, 06, 08, or 15,
17, 19, the following extended Group should be used for the Dch trunk: G27, 29, or 31.
shows an example where the cards are mounted in density Slots 04 or 05.
02 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
00
example
Figure 5-24 Mounting FCH and DTI Cards in Regular Density Slots
Figure 5-23 ACTK Command Display (example)
Figure
Figure 5-25
15
19
05
07
09 11
14
18
13
17
04
06 08
10
12
16
16 Port
32 Port
FRONT VIEW
NDA-24299
Assignment of Telephone Numbers
Figure 5-23
Figure
5-23.
C_RT: Connection Route (1-1023)
C_TK: Connection Trunk (1-4095)
C_LENS: Connection Line Equipment Numbers
5-24.
and
Figure
5-26.
23
01
03 05
22
21
00
02 04
20
16 Port
DATA PROGRAMMING