Displaying An Alarm Log - Siemens SINUMERIK 840D sl Universal Operating Manual

Hide thumbs Also See for SINUMERIK 840D sl Universal:
Table of Contents

Advertisement

Alarm, error, and system messages

17.2 Displaying an alarm log

17.2
Displaying an alarm log
A list of all the alarms and messages that have occurred so far are listed in the "Alarm Log"
window.
Up to 500 administered, incoming and outgoing events are displayed in chronological order.
Procedure
414
Machine manufacturer
Please refer to the machine manufacturer's specifications.
1.
Select the "Diagnostics" operating area.
2.
Press the "Alarm log" softkey.
The "Alarm Log" window opens.
All of the coming and going events - that have occurred since the HMI was
started - are listed.
3.
Press the "Display new" softkey to update the list of displayed alarms/
messages.
4.
Press the "Save Log" softkey.
The log that is currently displayed is stored as text file alarmlog.txt in the
system data in directory /user/sinumerik/hmi/log/alarm_log.
Operating Manual, 07/2021, 6FC5398-6AP40-6BA4
Universal