Host event tasks
7
Sources
32 | 66
Source
State (trigger)
Bank Floor Secure
Bank Floor UnSecure An event task is triggered when the floor is not
Card No Access
Other Floor Point
triggers are the same
as the Access Points,
however, relate to
elevator floor access.
Floor Point
Same as Floor Points See "Floor Point"
Group
Input Point
Alarm
Door Closed
Door Forced
Door Held
Input Tamper
Normal
Operator Alarm
Operator Alarm
Actioned
Operator Alarm Not
Actioned
Operator Alarm
Timed out
Operator Normal
Operator Restore
Operator Waiting for
Normal
Input Point
Same as Input Points See "Input Point"
Group
Intrusion Area
Alarm
Point
Description
An event task is triggered when the floor is
Secured.
secured.
An event task is triggered when a cardholder
badges their card and is not permitted access to
that floor.
See "Access Points" Above for more information.
An event task is triggered when the nominated
input point goes into alarm.
An event task is triggered when the nominated
input changes to a normal state as a result of the
door being closed.
An event task is triggered when the nominated
input goes into alarm, as a result of a door being
forced.
An event task is triggered when the nominated
input goes into alarm, as a result of a door being
held open longer than the specified time.
An event task is triggered when the nominated
input point group enters a Tamper state.
An event task is triggered when the nominated
input point goes into the normal state.
An event task is triggered when the nominated
input point goes into alarm.
An event task is triggered when an alarm,
associated with the nominated input point, is
actioned by an operator.
An event task is triggered when the operator fails
to action an alarm associated with the nominated
input point before the (re-activation) timeout.
An event task is triggered when the operator fails
to action the alarm associated with the input
point and the alarm times out.
An event task is triggered when the nominated
input point changes to a normal state.
An event task is triggered when the nominated
input point attains the 'Restored' status.
An event task is triggered when a restorable
alarm at the nominated input point has been
actioned, but has not returned to its normal state.
An event task is triggered when the nominated
area point goes into alarm.