Controller Event Tasks; Sources - Siemens SiPass integrated Reference Manual

Hide thumbs Also See for SiPass integrated:
Table of Contents

Advertisement

8 Controller Event Tasks

8.1 Sources

A6V11144326
SiPass integrated allows you to define a controller event task that performs a
certain task (command) when a specific set of circumstances have been met
(trigger).
Because controller event tasks are triggered by hardware events, you must select
what type of component triggers or responds to the event.
The following table lists the Types and States that can be selected when defining a
Trigger for a Controller Event Task.
Type
State (trigger)
ACC Event Task
Cleared
Set
Access Point
"Daily Code" mode
(logical)
set
"No Additional
Access" mode set
"No Dual Custody"
mode set
"PIN as Card" mode
set
"Standard Dual
Custody" mode set
"Supervisory Dual
Custody" mode set
Disable Intrusion
Control
Dual Custody
Verification
Complete
Enable Intrusion
Control
Invalid Daily Code
Reader Online
Reader Offline
Reader Tamper
Controller Event Tasks
Description
Allows the operator to trigger a Controller
Event Task as a result of another Controller
Event Task.
The ACC controller event task selected in the
Source field has not been triggered or has
been reset.
The ACC controller event task selected in the
Source field has been triggered.
Access Point mode set to Daily Code.
Access Point mode set to No Additional
Access.
Access Point mode set to No Dual Custody
mode.
Access Point mode set to Daily Code.
Access Point mode set to Daily Code.
Access Point mode set to Daily Code.
Intrusion Control is disabled on the access
point.
Dual Custody verification has been completed
at the access point.
Intrusion Control has been enabled at the
access point.
An event task is triggered when an invalid daily
code has been entered at an access point.
An event task is triggered when a reader
enters the offline state. Only valid for the
Siemens reader range.
An event task is triggered when a reader
enters the online state. Only valid for the
Siemens reader range.
An event task is triggered when a reader
enters the tamper state (tamper input
activated). Only valid for the Siemens reader
range.
8
Sources
41 | 66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents