Lenovo ThinkSystem SR630 Maintenance Manual page 258

Hide thumbs Also See for ThinkSystem SR630:
Table of Contents

Advertisement

• "Voltage planar fault is displayed in the event log" on page 249
• "Unusual smell" on page 249
• "Server seems to be running hot" on page 250
• "Cannot enter legacy mode after installing a new adapter" on page 250
• "Cracked parts or cracked chassis" on page 250
Server hangs during the UEFI boot process
If the system hangs during the UEFI boot process with the message UEFI: DXE INIT on the display, make sure
that Option ROMs were not configured with a setting of Legacy. You can remotely view the current settings
for Option ROMs by running the following command using the Lenovo XClarity Essentials OneCLI:
onecli config show EnableDisableAdapterOptionROMSupport --bmc xcc_userid:xcc_password@xcc_ipaddress
To recover a system that hangs during the boot process with Legacy Option ROM settings, see the following
Tech Tip:
https://datacentersupport.lenovo.com/us/en/solutions/ht506118
If legacy Option ROMs must be used, do not set slot Option ROMs to Legacy on the Devices and I/O Ports
menu. Instead, set slot Option ROMs to Auto (the default setting), and set the System Boot Mode to Legacy
Mode. Legacy option ROMs will be invoked shortly before the system boots.
The server immediately displays the POST Event Viewer when it is turned on
Complete the following steps until the problem is solved.
1. Correct any errors that are indicated by the light path diagnostics LEDs.
2. Make sure that the server supports all the processors and that the processors match in speed and
cache size.
You can view processor details from system setup.
To determine if the processor is supported for the server, see
serverproven/index.shtml
3. (Trained technician only) Make sure that processor 1 is seated correctly
4. (Trained technician only) Remove processor 2 and restart the server.
5. Replace the following components one at a time, in the order shown, restarting the server each time:
a. (Trained technician only) Processor
b. (Trained technician only) System board
Server is unresponsive (POST is complete and operating system is running)
Complete the following steps until the problem is solved.
• If you are in the same location as the compute node, complete the following steps:
1. If you are using a KVM connection, make sure that the connection is operating correctly. Otherwise,
make sure that the keyboard and mouse are operating correctly.
2. If possible, log in to the compute node and verify that all applications are running (no applications are
hung).
3. Restart the compute node.
4. If the problem remains, make sure that any new software has been installed and configured correctly.
5. Contact your place of purchase of the software or your software provider.