Power on the server
After the server performs a short self-test (power status LED flashes quickly) when connected to input power,
it enters a standby state (power status LED flashes once per second).
The server can be turned on (power LED on) in any of the following ways:
• You can press the power button.
• The server can respond to remote power-on requests sent to Lenovo XClarity Controller via Lenovo
XClarity Essentials OneCLI, IPMItool, or SSH CLI.
For example, run the following command on Lenovo XClarity Essentials OneCLI to power on your server:
OneCli.exe ospower turnon --bmc USERID:PASSW0RD@host
For more information about running the o o s s p p o o w w e e r r command, see
toolsctr_cli_lenovo/onecli_r_ospower_command.html
If the system UEFI power policy is set to "always on", the system will be powered on automatically when an
AC source is plugged in.
For information about powering off the server, see "Power off the server" on page 16.
System boot/startup time
The system boot/startup time varies by hardware configurations and may change depending on your server
configuration and conditions.
• For typical configurations without PMEM memory modules, it takes about 3 minutes for the system to
start up.
Configuration example: 2 x processors, 16 x RDIMMs, 1 x RAID adapter, 1 x NIC adapter
• For configurations with PMEM memory modules installed, it may take up to 15 minutes for the system to
start up.
Configuration example: 2 x processors, 16 x RDIMMs, 16 x PMEMs, 1 x RAID adapter, 1 x NIC adapter
• For configurations with PMEM memory modules installed and Intel Volume Management Device (VMD)
enabled, it may take about 20 minutes or longer for the system to start up.
Configuration example: 2 x processors, 16 x RDIMMs, 16 x PMEMs, 1 x RAID adapter, 1 x NIC adapter
Power off the server
The server remains in a standby state when it is connected to a power source, allowing the BMC to respond
to remote power-on requests. To remove all power from the server (power status LED off), you must
disconnect all power cables.