Diagnostic system
7.3 Faults
7.3.2

System Config

Bit 0
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 1
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 2
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 3
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 4
Message class
Component
Response
Acknowledgement
Cause
Remedy
116
Deactivating Unit 1 failed
Fault
Hardware configuration of ESS IF PLC
Shutdown routine 3
Warm restart of ESS IF PLC
Deactivation of SINAMICS DCP1 failed
Check the input inHWAddr_Head (Page 53)
Deactivating Unit 2 failed
Fault
Hardware configuration of ESS IF PLC
Shutdown routine 3
Warm restart of ESS IF PLC
Deactivation of SINAMICS DCP2 failed
Check the input inHWAddr_Head (Page 53)
Deactivating Unit 3 failed
Fault
Hardware configuration of ESS IF PLC
Shutdown routine 3
Warm restart of ESS IF PLC
Deactivation of SINAMICS DCP3 failed
Check the input inHWAddr_Head (Page 53)
Deactivating Unit 4 failed
Fault
Hardware configuration of ESS IF PLC
Shutdown routine 3
Warm restart of ESS IF PLC
Deactivation of SINAMICS DCP4 failed
Check the input inHWAddr_Head (Page 48)
Default Drive configuration invalid
Fault
Hardware configuration of ESS IF PLC
Shutdown routine 3
Warm restart of ESS IF PLC
Incorrect parameterization of input inNrOfDCPSInSystem[X]
Check the input inNrOfDCPSInSystem[X] (Page 48)
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE