Siemens SIMOCRANE Operating Instructions Manual page 46

Energy storage system management v01.01
Table of Contents

Advertisement

Block interface
5.1 Inputs
Table 5-18
inReceiveFromMaster.VBatMin
Input
inReceiveFromMaster.VBatMin
Table 5-19
inReceiveFromMaster.WatchDog
Input
inReceiveFromMaster.WatchDog
Table 5-20
inReceiveFromMaster.BMS
Input
inReceiveFromMaster.BMS
Table 5-21
inReceiveFromMaster.BMS.Battery
Input
inReceiveFromMaster.BMS.Bat‐
tery
Table 5-22
inReceiveFromMaster.BMS.Battery
Name
Voltage
Power
Current
SOC
BATChargeCurrLimit
BATDischargeCurrLimit
AVRGTemp
AVRGCellVoltage
44
Name
Data
type
VBatMin
Real
Name
Data
type
WatchDog
Integer
Name
Data
type
BMS
LTypes_B
MS_Bat‐
tery
Name
Data
type
Battery
Struct
Data type
Unit
Real
V
Real
kW
Real
A
Real
%
Real
A
Real
A
Real
°C
Real
V
Higher-level data
Comment
type
inReceiveFromMaster An alarm is output when this low‐
er voltage limit is reached
Higher-level data
Comment
type
inReceiveFromMaster This is used to read the watchdog
value from the higher-level con‐
trol. Write back the value which
you receive via the receive chan‐
nel in the higher-level control
here.
Higher-level data
Comment
type
inReceiveFromMaster -
Higher-level data
Comment
type
BMS
-
Comment
Actual battery voltage
Actual power of the battery
Actual current of the battery
Actual charge level of the battery
Actual charge current with which the battery can be
charged (> 50.0)
Actual discharge current with which the battery can be
discharged (> 50.0)
Average temperature of cells
Average cell voltage
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE

Advertisement

Table of Contents
loading

Table of Contents