Table 5-45
outSendToMaster.StatusWord1
Bit
Name
Bit 0
EnergyFlowDir1
Bit 1
EnergyFlowDir1
Bit 2
HighDynamicSelec‐
ted
Bit 3
BypassVdclinkSelec‐
ted
Bit 4
BlackStartMode
Bit 5
ManualModeActive
Bit 6
PeakShavingModeac‐
tive
Bit 7
LocalControlActive
Bit 8
RemoteControlActive Bool
Bit 9
CommissioningMo‐
deActive
Bit 10
Ready
Bit 11
OverloadSelected
Bit 12
HybridSelected
Bits 13-15 Spare
Table 5-46
outSendToMaster.StatusWord2
Output
outSendToMaster.StatusWord2
Table 5-47
outSendToMaster.StatusWord2
Bit
Name
Bit 0
ReadyToSwitchOn
Bit 1
Running
Bit 2
Stopped
Bit 3
Charging
Bit 4
Discharging
Bit 5
Booting
Bit 6
ShuttingDown
Bit 7
Warning
Bit 8
Fault
Bit 9
InternalStopAct
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE
Data type
Comment
Bool
Energy flow from the battery to the DC link
Bool
Energy flow from the DC link to the battery
Bool
The "High Dynamic" function is activated
Bool
The "Bypass" function is activated
Bool
"Black Start" mode is selected
Bool
"Manual Charge & Discharge" mode is selected
Bool
Fully automatic "Peak Shaving" mode is selected
Bool
The local interface is being used for operation
The remote control (crane PLC) is being used for operation
Bool
The local interface is being used for operation and in addition the
commissioning mode for setting special parameters is active
Bool
Initialized and hardware detected, all OK
Bool
Overload mode is activated
Bool
Hybrid mode is activated
Bool
These bits are not used
Name
Data
type
StatusWord2
Struct
Data type
Comment
Bool
The system is ready to switch on
Bool
The system is running
Bool
The system has been stopped
Bool
SIMOCRANE ESSM is operating in "Manual Mode" and the batteries
are being charged
Bool
SIMOCRANE ESSM is operating in "Manual Mode" and the batteries
are being discharged
Bool
The system has been switched on and is in boot mode
Bool
The system has been switched off and is shutting down
Bool
A warning is active (see warning codes)
Bool
A fault is present (see fault codes)
Bool
Internal stop active (see warning and fault codes)
Higher-level data
Comment
type