Block interface

When "LEssMgmt_Main" is called in the user program, the block interface is displayed (see the
figure "Block interface" below). The interface consists of inputs and outputs, which are described
in the following chapters.
Note
Call of "LEssMgmt_Main"
The call of "LEssMgmt_Main" in the user program must take place in a fixed time OB
(organization block) screen with a cycle time of ≤ 4 ms.
Note
Restart
The PLC should be restarted (Stop/Run) after any change in the parameters of the block interface.
Damage to the battery due to the transfer of incorrect battery data
The battery can be damaged as a result of transferring incorrect battery data.
• Make sure that the correct battery data have been transferred.
• Protect the data transfer against unauthorized access.
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE