Table 6-2
DCP_Receive.StatusWord1
STW1
DCP_Receive.StatusWord1
Table 6-3
DCP_Receive.StatusWord1
Bit
Name
Bit 0
ReadyToPowerUp
[r899.0]
Bit 1
Standby [r899.1]
Bit 2
Run [r899.2]
Bit 3
FaultActive [r2139.3] Bool
Bit 4
PowerOnInhibit
[r899.6]
Bit 5
OFF2Inactive
[r899.4]
Bit 6
AlarmActive
[r2139.7]
Bit 7
Spare
Bit 8
Spare
Bit 9
MasterCotrolReq
[r899.9]
Bit 10
Spare
Bit 11
ImpulsesEnabled
[r899.11]
Bit 12
LineContClse
[r55375.3]
Bit 13
PreChrgeContClse
[r55375.2]
Bit 14
ChrgCurrLimAct
[r55125.0]
Bit 15
DischrgCurrLimAct
[r55125.1]
Table 6-4
DCP_Receive.StatusWord2
STW
DCP_Receive.StatusWord2
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE
Name
Data
type
StatusWord1
Word
Data type
Comment
Bool
Ready to power up
Bool
Ready for operation
Bool
Operation enabled
A fault is active
Bool
Switch-on inhibit active
Bool
OFF2 inactive
Bool
A warning (alarm) is active
Bool
-
Bool
-
Bool
Master control by PLC requested
Bool
-
Bool
Pulses enabled
Bool
DCP requests closing of the bypass contactor
Bool
DCP requests closing of the precharge contactor
Bool
Charge current limit reached
Bool
Discharge current limit reached
Name
Data
type
StatusWord2
Word
6.4 Controlling the power converters
Higher-level data
Comment
type
DCP_Receive
-
Higher-level data
Comment
type
DCP_Receive
Spare
Control and engineering
89