Lenovo ThinkSystem SR665 V3 User Manual page 129

Hide thumbs Also See for ThinkSystem SR665 V3:
Table of Contents

Advertisement

• To make sure that there is adequate system cooling, do not operate the server for more than two minutes
without either a drive or a drive bay filler installed in each bay.
• Before you make changes to drives, drive controllers (including controllers that are integrated on the
system board assembly), drive backplanes, or drive cables, back up all important data that is stored on
drives.
Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinksystem/sr665v3/downloads/driver-list/
see the latest firmware and driver updates for your server.
• Go to
"Update the firmware" on page 467
Procedure
Step 1.
Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2.
Install the 3.5-inch drive backplane.
Note: Depending on the specific type, your backplane might look different from the illustration.
Figure 75. Installing the 3.5-inch drive backplane
a.
Align the backplane with the chassis and lower it into the chassis. Then, put the backplane
into place with it leaning backward slightly.
b.
Rotate the backplane to vertical position to ensure that the four hooks on the chassis pass
through the corresponding holes in the backplane. Then, slide the new backplane as shown
until it is secured into place.
for more information on firmware updating tools.
Chapter 5
.
Hardware replacement procedures
to
119