Lenovo ThinkSystem SR665 V3 User Manual page 16

Hide thumbs Also See for ThinkSystem SR665 V3:
Table of Contents

Advertisement

Network
• OCP module in the rear or front of the server, which provides two or four Ethernet connectors for network support
Note: If ThinkSystem Redundant System Management Port Adapter is installed on the server, it will not be
displayed on the PCIe card list of system management software, such as XCC, LXPM, and so on.
System fan
• Supported fan types:
– Standard fan 6038 (single-rotor, 17000 RPM)
– Performance fan 6056 (dual-rotor, 21000 RPM)
• Fan redundancy: N+1 redundancy, one redundant fan rotor
– One processor: five hot-swap system fans (one redundant fan rotor)
– Two processors or one processor with middle/rear bay or Riser 3: six hot-swap system fans (one redundant fan
rotor)
Notes:
• Single-rotor hot-swap fans cannot be mixed with dual-rotor hot-swap fans.
• The redundant cooling by the fans in the server enables continued operation if one rotor of a fan fails.
• When the system is powered off but still plugged in to AC power, fans 1 and 2 may continue to spin at a much lower
speed. This is the system design to provide proper cooling.
Power supplies
The server supports up to two hot-swap power supplies for redundancy.
Power supply
750W Platinum
750W Titanium
1100W Platinum
1100W Titanium
1800W Platinum
1800W Titanium
2400W Platinum
2600W Titanium
1100W -48V DC
CAUTION:
• 240 V dc input (input range: 180-300 V dc) is supported in Chinese Mainland ONLY.
• Power supply with 240 V dc input cannot support hot plugging power cord function. Before removing the
power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by
turning off the power source. Then, remove the power cord.
Minimal configuration for debugging
• One processor in socket 1
• One memory module in slot 7
• One power supply unit
• One HDD/SSD drive, one M.2 drive, or one 7mm drive (if OS is needed for debugging)
• Five system fans
ThinkSystem SR665 V3 User Guide
6
100–127 V ac
200–240 V ac
240 V dc
-48 V dc

Advertisement