Note: If your CMA kit obstructs in the way, slightly pull the power supply unit upwards when sliding
the power supply unit out of the chassis.
Figure 127. Removing the power supply unit
After you finish
1. Install a new power supply unit or install the power-supply filler to cover the power supply bay. See
"Install a power supply unit" on page
Important: To ensure proper cooling during normal server operation, both of the power supply bays
must be occupied. This means that each bay must have a power supply unit installed; or one has a
power supply unit installed and the other has a power supply filler installed.
2. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Demo video
Watch the procedure on YouTube

Install a power supply unit

Follow instructions in this section to install a power supply unit.
About this task
If you are replacing the existing power supply unit with a new one:
• Use Lenovo Capacity Planner to calculate the required power capacity for what is configured for your
server. More information about Lenovo Capacity Planner is available at:
https://datacentersupport.lenovo.com/solutions/lnvo-lcp
• Ensure that the devices that you are installing are supported. For a list of supported optional devices for
the server, go to:
https://serverproven.lenovo.com/
• Attach the power information label that comes with this option onto the existing label near the power
supply unit.
ThinkSystem SR665 V3 User Guide