Variable
<m/t_model>
<s/n>
<system model>
<asset_tag>
[access_method]
System fan replacement
Follow instructions in this section to remove and install a system fan.
•
"Remove a system fan" on page 264
•
"Install a system fan" on page 266
Remove a system fan
Follow instructions in this section to remove a system fan.
About this task
ThinkSystem SR665 V3 User Guide
264
Description
The server machine type and model number.
Type xxxxyyy, where xxxx is the machine type and yyy is the server model number.
The serial number on the server.
Type zzzzzzz, where zzzzzzz is the serial number.
The system model on the server.
Type system yyyyyyyy, where yyyyyyyy is the product identifier.
The server asset tag number.
Type aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa, where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is
the asset tag number.
The access method that you select to access the target server.
• Online KCS (unauthenticated and user restricted):
You can directly delete [access_method] from the command.
• Online authenticated LAN:
In this case, specify below LAN account information at the end of the OneCLI
command:
--bmc-username <user_id> --bmc-password <password>
• Remote WAN/LAN:
In this case, specify below XCC account information and IP address at the end of the
OneCLI command:
--bmc <bmc_user_id>:<bmc_password>@<bmc_external_IP>
Notes:
– <bmc_user_id>
The BMC account name (1 of 12 accounts). The default value is USERID.
– <bmc_password>
The BMC account password (1 of 12 accounts).