Install A Hot-Swap Drive - Lenovo ThinkSystem SR665 V3 User Manual

Hide thumbs Also See for ThinkSystem SR665 V3:
Table of Contents

Advertisement

2.5-inch hot-swap drive
After you finish
1. Install a new drive or drive filler to cover the drive bay. See
2. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Demo video
Watch the procedure on YouTube

Install a hot-swap drive

Follow instructions in this section to install a hot-swap drive.
About this task
Attention:
• Read
"Installation Guidelines" on page 47
work safely.
• To make sure that there is adequate system cooling, do not operate the server for more than two minutes
without either a drive or a drive bay filler installed in each bay.
For a list of supported drives, see
Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinksystem/sr665v3/downloads/driver-list/
see the latest firmware and driver updates for your server.
• Go to
"Update the firmware" on page 467
Procedure
Step 1.
Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2.
Install the drive in the drive bay.
a.
Ensure that the drive tray handle is in the open position. Slide the drive into the drive bay
until it snaps into position.
ThinkSystem SR665 V3 User Guide
134
and
"Safety inspection checklist" on page 48
https://serverproven.lenovo.com/
for more information on firmware updating tools.
3.5-inch hot-swap drive
"Install a hot-swap drive" on page
.
134.