4 Individual remote controls
PC-LH3(A/B)

4.4.4 Operation


Before operation
C A U T I O N
Turn on the electrical power supply to the system approximately 12 hours before start-up after a long shutdown. Do not start the sys-
tem immediately after connecting the power supply, because the compressor may be damaged if it is not sufficiently heated.
Make sure the outdoor unit is not covered with ice or snow. If it is, remove the ice or snow with warm water (no hotter than 50°C). If
the water temperature is over 50°C, the plastic parts may be damaged.
When the system is started after being out of use for more than 3 months, we recommend that the system is checked by the service
provider.
If the system is not going to be used for a long period of time, turn it off at the mains. Otherwise it will continue to consume electricity,
since the oil heater remains on even when the compressor is off.
N O T E
The "
" lamp (yellow) is turned ON with the beep sound for receipt confirmation.
The beep sound may not be heard by surrounding noise.
"
" lamp (yellow) on the receiver of the indoor unit flashes (0.25 seconds ON 0.25 seconds OFF), and then turns OFF. While the
"
" lamp is flashing, the unit will not operate because it is initializing.

4.4.4.1 Basic operation


Start operation
Press "MODE" switch. By repeatedly pressing "MODE" switch, the unit cycles through the different operating modes in the
order of HEAT, DRY, COOL and FAN.
The indications of setting temperature, fan speed and air flow angle may be turned ON depending on the condition of
control.
N O T E
Refer about automatic cooling/heating operation mode to the item Automatic cooling/heating operation
Point the transmitter towards the receiver kit and press "RUN/STOP" switch. When the transmitting indication "
on the LCD of wireless remote control switch, the "
indicator (red) on receiver is turned ON when the operation is started.
N O T E
Do not press "RUN/STOP" switch repeatedly (less than 3 seconds). If the switch is pressed frequently, the controller may not work cor-
rectly.

Temperature, fan speed and air flow direction setting
Once the setting is confirmed, the setting condition will be stored. Therefore the daily setting is not required. In case that
the setting change is required, refer to the item Setting Method.
176
TCGB0106 rev.0 - 12/2014
Cooling mode is
under operating
COOL
" lamp (yellow) on the receiver will be turned on briefly. The RUN
The indications of setting temperature, fan
speed and air flow angle are turned ON.