4.2.3 Syslog Settings

SYSLOG_EVENT_SIP
Value Format
Description
Value Range
Default Value
SYSLOG_EVENT_CFG
Value Format
Description
Value Range
Default Value
SYSLOG_EVENT_VOIP
Value Format
Description
Value Range
Default Value
SYSLOG_EVENT_TEL
Value Format
Description
Document Version 2013-03
Integer
Specifies which SIP-related syslog events are sent to the syslog server.
Note
If the level of the event is higher than or equal to the set value,
the log is sent to the syslog server.
0–6
0: no logs sent
1: emergency (highest)
2: alert
3: critical
4: error
5: warning
6: information (lowest)
0
Integer
Specifies the threshold of syslog events regarding configuration.
0–6
0
Integer
Specifies the threshold of syslog events regarding VoIP operation.
0–6
0
Integer
Specifies the threshold of syslog events regarding telephone functions.
Note
This setting is not applicable for the current version. No logs will
be sent to the syslog server, even if values "1–6" are specified.