Cfg_Resync_Time - Panasonic KX-UDS124 Administrator's Manual

Cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

4.2.6 Other Settings

CFG_RESYNC_TIME

Value Format
Description
Value Range
Default Value
CFG_RESYNC_FROM_SIP
Value Format
Description
Value Range
Default Value
4.2.6 Other Settings
IPEI_PSy
Value Format
Description
Value Range
Default Value
SIP_REGI_PS_LIMIT
Value Format
184
Administrator Guide
String
Specifies the time (hour:minute) that the SIP-CS checks for updates of
configuration files.
00:00–23:59
Note
If the value for this setting is any valid value other than an empty
string, the SIP-CS downloads the configuration files at the fixed
time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are
disabled.
If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Empty string
String
Specifies the value of the "Event" header sent from the SIP server to
the SIP-CS so that the SIP-CS can access the configuration files on the
provisioning server.
Max. 15 characters
Note
An empty string is not allowed.
check-sync
String
Specifies the S-PS's IPEI, which is used when registering the S-PS to
the SIP-CS.
12 digits
Empty string
Integer
Document Version 2013-03