Description
Value Range
Default Value
BELL_CORE_PATTERN5_TIMING
Value Format
Description
Value Range
Default Value
4.4.3 Telephone Settings
NUMBER_MATCHING_LOWER_DIGIT
Value Format
Description
Value Range
Default Value
NUMBER_MATCHING_UPPER_DIGIT
Value Format
Description
Value Range
Default Value
Document Version 2013-03
Specifies the cadence, in milliseconds, of pattern ID 4, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
Note
•
Avoid setting 1–99 for any of the values.
0–5000 (0: Infinite time)
300,200,1000,200,300,4000
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 5, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
Note
•
Avoid setting 1–99 for any of the values.
0–5000 (0: Infinite time)
500
Integer
Specifies the minimum number of digits with which to match a
phonebook entry with an incoming call's caller ID. To specify exact
matching of entire numbers only, specify "0".
0–15
7
Integer
Specifies the maximum number of digits with which to match a
phonebook entry with an incoming call's caller ID. To specify exact
matching of entire numbers only, specify "0".
0–15
10
4.4.3 Telephone Settings
Administrator Guide