Troubleshooting - Panasonic KX-UDS124 Administrator's Manual

Cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

10.1 Troubleshooting

10.1 Troubleshooting
Status indicator
Status
Off
Red on
Red flashing
rapidly
Red flashing
Amber on
Amber flashing
Amber flashing
rapidly
Green on
Green flashing
Green flashing
rapidly
When a user makes a call and the cell station is busy, the user sees the message "CS Busy" on the S-PS's display.
*1
278
Administrator Guide
Problem
The unit is not receiving
power.
Device error
A network failure
occurred during
startup.
The SIP-CS could
not register with the
SIP server on
startup.
The SIP-CS is waiting
for air synchronization.
An air synchronization
error has occurred.
An air synchronization
error has occurred
(while an S-PS is in use).
An air synchronization
error has occurred and
the SIP-CS is in a busy
state.
Normal
Normal (while an S-PS is
in use)
The SIP-CS is in a busy
state.
Cause/Solution
The unit is not designed to function when there is a power
failure. Make sure that the device supplying PoE is receiving
power and that the Ethernet cable is properly connected. If an
AC adaptor is connected, confirm that the AC adaptor is
connected and receiving power.
Consult your dealer.
Check network settings.
Check that settings are correct for registration to the SIP
server.
If this state continues for a while, check the CS monitor screen
in the Web user interface.
1.
Click the [System] tab, and then click [CS Monitor].
2.
Select [Air Sync Group].
3.
Check the CS monitor screen.
Check the CS monitor screen in the Web user interface.
1.
Click the [System] tab, and then click [CS Monitor].
2.
Select [Air Sync Group].
3.
Check the CS monitor screen.
Check the CS monitor screen in the Web user interface.
1.
Click the [System] tab, and then click [CS Monitor].
2.
Select [Air Sync Group].
3.
Check the CS monitor screen.
Check the CS monitor screen in the Web user interface.
1.
Click the [System] tab, and then click [CS Monitor].
2.
Select [Air Sync Group].
3.
Check the CS monitor screen.
If users frequently experience busy conditions, put an
additional cell station near the frequently busy cell station.
*1
Document Version 2013-03

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents