Reorder_Tone_Rpt - Panasonic KX-UDS124 Administrator's Manual

Cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

4.4.2 Tone Settings
Description
Value Range
Default Value

REORDER_TONE_RPT

Value Format
Description
Value Range
Default Value
REORDER_TONE_TIMING
Value Format
Description
Value Range
Default Value
RINGBACK_TONE_FRQ
Value Format
Description
Value Range
Default Value
RINGBACK_TONE_GAIN
Value Format
Description
Value Range
202
Administrator Guide
Specifies the gain, in decibels, of the reorder tone.
-24–6
0
Integer
Specifies whether the reorder tone is repeated.
0–1
0: No Repeat
1: Repeat
1
Comma-separated Integer
Specifies the pattern, in milliseconds, of reorder tones using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Avoid setting 1–50 for any of the values.
0–16000 (0: Infinite time)
60,250,190
Comma-separated Integer
Specifies the dual-tone frequencies, in hertz, of ringback tones using 2
whole numbers separated by a comma.
0, 200–2000 (0: No tone)
440,480
Integer
Specifies the gain, in decibels, of the ringback tone.
-24–6
Document Version 2013-03