Ps Registration Using Provisioning - Panasonic KX-UDS124 Administrator's Manual

Cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

5.2 PS Registration using Provisioning

4.
Select the base number for unregistration by pressing
Note
You can select multiple base numbers for unregistration if necessary.
Cancel Base
Base 1
Base 2
Base 3
Base 4
5.
Select "Yes" and then press
When unregistration has completed, "Deleted" will be displayed.
Deleted
5.2 PS Registration using Provisioning
This section shows how to register the S-PS via configuration file programming.
You must prepare a configuration file (e.g., UserAccount.cfg) for each user account, as follows:
# Panasonic SIP Phone Standard Format File # DO NOT CHANGE THIS LINE!
# Setting for PS1
# 12 digits IPEI code for registering PS
IPEI_PS1="123456789012"
# Line1 Setting
PHONE_NUMBER_PS1_1="3331231"
SIP_AUTHID_PS1_1="userid1"
SIP_PASS_PS1_1="userpass1"
# Line2 Setting
PHONE_NUMBER_PS1_2="3331232"
SIP_AUTHID_PS1_2="userid2"
The IPEI code is a unique number throughout the world. Therefore, you can register S-PSs remotely by stating
the IPEI in a configuration file.
After the above configuration file is provisioned, all SIP-CSs enter PS Registration mode until the specified
S-PS registration is performed.
You can confirm the IPEI code of your S-PS either from the label of its package or via the S-PS's system option
menu.
248
Administrator Guide
.
, and then press
Document Version 2013-03
.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading