9.
Secure the STRENGTHEN PLATE, CR with two screws.
Two C.B.P. 3 x 8 screws (3 ± 0.5 kgf.cm)
When installing the STRENGTHEN PLATE, CR to the
CARRIAGE, ASSY., be sure to insert the positioning hole of the
STRENGTHEN PLATE, CR over the guide pins of the
CARRIAGE, ASSY.
10. Connect the all connectors and FFCs to the BOARD ASSY., SUB.
Connect the FFCs to their correct positions matching the
numbers written on the FFCs with those printed on the board
as shown in
Figure 4-112
Route the cables of the APG SENSOR (CN4) keeping them
from contact with the spring as shown below.
Spring
APG SENSOR
11. Secure the grounding wire to the BOARD ASSY., SUB with the screw.
One C.B.S. 3 x 6 screw (6 ± 1 kgf.cm)
DISASSEMBLY & ASSEMBLY
See Figure 4-113.
See Figure 4-113.
and
Table
4-6.
Cables
CN4
Disassembly/Assembly Procedure (Group 1)
Table 4-6. List of Connectors on the BOARD ASSY., SUB
Connector No. Color
Number of Pins
CN1
(FFC)
17
CN2
White
2
CN3
(FFC)
4
CN4
White
3
CN5
Black
3
CN6
(FFC)
8
CN5
CN2
Figure 4-112. Connector Layout of the BOARD ASSY., SUB
The board and the grounding
C.B.S. 3x6
terminal are secured together.
BOARD ASSY., SUB
Positioning point
Figure 4-113. Installing the BOARD ASSY., SUB
Revision C
Destination
BOARD ASSY., MAIN
MOTOR, INK SELECTOR
INK MARK SENSOR
APG SENSOR
SWITCH, INK SELECTOR
BOARD ASSY., DETECT, PW; B
CN4
CN6
CN3
CN1
C.B.P. 3x8
STRENGTHEN
PLATE, CR
176