8.53 Process Drive Unit
(1) Disconnect the wiring of the Back cover sensor harness.
(2) Remove the two Taptite cup S M3x8 SR screws to remove the Flat cable guide.
Flat cable guide
Main PCB insulation sheet
<Left side>
(3) Release the two Hooks to remove the Main PCB insulation sheet from the Side frame L
ASSY.
Main PCB insulation sheet
<Left side>
Fig. 3-180
Hook
Side frame L ASSY
Fig. 3-181
3-129
Taptite cup S M3x8 SR
Hook
Confidential