(9) Release the two Bosses to remove the LVPS insulation sheet lower from the Low-voltage
power supply PCB ASSY.
Main body
Boss
(10) Release the two Bosses to remove the Low-voltage power supply PCB ASSY from the
Main body.
(11) Disconnect the Connector (CN101) from the Low-voltage power supply PCB ASSY.
CN101
Connector
Main body
Boss
Harness routing: Refer to
LVPS insulation sheet lower
Fig. 3-234
Low-voltage power supply PCB ASSY
11
10
Fig. 3-235
"
Low-voltage Power Supply PCB ASSY"
3-160
Low-voltage power supply
PCB ASSY
Confidential