Brother MFC-9130CW Service Manual page 95

Color fax/mfc
Hide thumbs Also See for MFC-9130CW:
Table of Contents

Advertisement

■ Error code 6B01
Drum Stop
Replace the Drum Unit. Refer to the instructions in the carton of the new drum.
Electric discharge was detected when the number of the drum unit (Black) rotations had
become more than twice of the upper limit.
Error code 6B02
Drum Stop
Replace the Drum Unit. Refer to the instructions in the carton of the new drum.
Electric discharge was detected when the number of the drum unit (Yellow) rotations had
become more than twice of the upper limit.
Error code 6B03
Drum Stop
Replace the Drum Unit. Refer to the instructions in the carton of the new drum.
Electric discharge was detected when the number of the drum unit (Magenta) rotations had
become more than twice of the upper limit.
Error code 6B04
Drum Stop
Replace the Drum Unit. Refer to the instructions in the carton of the new drum.
Electric discharge was detected when the number of the drum unit (Cyan) rotations had
become more than twice of the upper limit.
<User Check>
- Replace the drum unit.
Step
1
Dirt on the GRID terminals of
the main body
2
Dirt on the terminal of the
high-voltage power supply PCB
3
High-voltage power supply PCB
failure
4
Main PCB failure
Cause
2-56
Remedy
Clean the GRID terminals of the main
body. (Refer to
fig. 2-7
Clean the terminal of the high-voltage
power supply PCB.
Replace the high-voltage power supply
PCB ASSY.
Replace the main PCB ASSY.
(P2-50))
Confidential

Advertisement

Table of Contents
loading

Table of Contents