130
Code Description
4232 CORRECTION SRC
Defines the trimming reference for the correction source.
1 =
2
– Uses appropriate
PID
REF
• 1105
1
REF
MAX
• 1108
2
REF
MAX
2 =
2
– Uses the absolute maximum speed or frequency (Switch C):
PID
OUTPUT
• 2002
MAXIMUM SPEED
• 2008
MAXIMUM FREQUENCY IF
Ramped ref
Switch
Ext ref 1 max (A)
Ext ref 2 max (B)
Abs Max Speed
Freq (C)
PID2 ref
Start-Up
(S
REF MAX
WITCH
when
1 is active (A).
REF
when
2 is active (B).
REF
if 9904
MOTOR CONTROL MODE
9904
MOTOR CONTROL MODE
Select
(par. 4230)
off
propor.
direct
PID 2
A
B):
OR
= 1
or 2
SPEED
TORQUE
= 3
.
SCALAR
Mul.
trim scale
X
Select
(par. 4232)
Trimming PID2 ref
Trimming PID2 out
ACS550 User's Manual
.
Add
Trimmed ref
+
Mul.
X