ACS550 User's Manual
Code Description
35 =
– Energize relay based on input from fieldbus communication.
COMM
• Fieldbus writes binary code in parameter 0134 that can energize relay 1...relay 6 according to the following:
Par. 0134
Binary
0
000000
1
000001
2
000010
3
000011
4
000100
5...62
63
111111
• 0 = De-energize relay, 1 = Energize relay.
36 =
(-1) – Energize relay based on input from fieldbus communication.
COMM
• Fieldbus writes binary code in parameter 0134 that can energize relay 1...relay 6 according to the following:
Par. 0134 Binary
0
000000
1
000001
2
000010
3
000011
4
000100
5...62
63
111111
• 0 = De-energize relay, 1 = Energize relay.
37 =
TIMER FUNCTION
38...40 =
TIMER FUNCTION
41 =
.
– Energize relay when cooling fan counter is triggered. See Group 29, Maintenance Trig.
M
TRIG FAN
42 =
.
– Energize relay when revolutions counter is triggered. See Group 29, Maintenance Trig.
M
TRIG REV
43 =
.
– Energize relay when run time counter is triggered. See Group 29, Maintenance Trig.
M
TRIG RUN
44 =
.
– Energize relay when MWh counter is triggered. See Group 29, Maintenance Trig.
M
TRIG MWH
45 =
– Relay is not used and is de-energized.
RESERVED
1402 RELAY OUTPUT 2
Defines the event or condition that activates relay 2 – what relay output 2 means.
• See 1401
RELAY OUTPUT
1403 RELAY OUTPUT 3
Defines the event or condition that activates relay 3 – what relay output 3 means.
• See 1401
RELAY OUTPUT
1404 RO 1 ON DELAY
Defines the switch-on delay for relay 1.
• On / off delays are ignored when relay output 1401 is set to PFC.
1405 RO 1 OFF DELAY
Defines the switch-off delay for relay 1.
• On / off delays are ignored when relay output 1401 is set to PFC.
1406 RO 2 ON DELAY
Defines the switch-on delay for relay 2.
• See
1
RO
ON DELAY
1407 RO 2 OFF DELAY
Defines the switch-off delay for relay 2.
• See
1
RO
OFF DELAY
1408 RO 3 ON DELAY
Defines the switch-on delay for relay 3.
• See
1
RO
ON DELAY
RO6 RO5 RO4 RO3 RO2 RO1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
...
...
...
...
1
1
1
RO6
RO5 RO4 RO3 RO2 RO1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
...
...
...
...
0
0
0
1 – Energize relay when Timer Function 1 is active. See Group 36, Timer Functions.
2...4 – Energize relay when Timer Function 2...4 is active. See Timer Function 1 above.
1.
1.
.
.
.
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
...
...
...
1
1
1
1
1
1
1
1
0
1
0
1
1
0
0
0
1
1
...
...
...
0
0
0
Control event
Relay status
1404
1405
ON DELAY
OFF DELAY