Fault History - ABB ACS550-01 User Manual

Drive low voltage ac drives
Hide thumbs Also See for ACS550-01:
Table of Contents

Advertisement

72
Group 04: Fault History
This group stores a recent history of the faults reported by the drive.
Code Description
0401 LAST FAULT
0 = Clear the fault history (on panel = NO RECORD).
n = Fault code of the last recorded fault.
0402 FAULT TIME 1
The day on which the last fault occurred. Either as:
• A date – if real time clock is operating.
• The number of days after power on – if real time clock is not used, or was not set.
0403 FAULT TIME 2
The time at which the last fault occurred. Either as:
• Real time, in format hh:mm:ss – if real time clock is operating.
• The time since power on (less the whole days reported in 0402), in format hh:mm:ss – if real time clock is not used,
or was not set.
0404 SPEED AT FLT
The motor speed (rpm) at the time the last fault occurred.
0405 FREQ AT FLT
The frequency (Hz) at the time the last fault occurred.
0406 VOLTAGE AT FLT
The DC bus voltage (V) at the time the last fault occurred.
0407 CURRENT AT FLT
The motor current (A) at the time the last fault occurred.
0408 TORQUE AT FLT
The motor torque (%) at the time the last fault occurred.
0409 STATUS AT FLT
The drive status (hex code word) at the time the last fault occurred.
0410 DI 1-3 AT FLT
The status of digital inputs 1...3 at the time the last fault occurred.
0411 DI 4-6 AT FLT
The status of digital inputs 4...6 at the time the last fault occurred.
0412 PREVIOUS FAULT 1
Fault code of the second last fault. Read-only.
0413 PREVIOUS FAULT 2
Fault code of the third last fault. Read-only.