Hardware Information
+CBAUD, Baud Rate Regulation
This command sets the baud rate. The baud rate of the G24-L is changed/set to the request value
<rate> written in the command.
Specifying a value of 9 or 0 disables the function and allows operation only at rates automatically
detectable by the G24-L. The specified rate takes effect following the issuing of any result
code(s) associated with the current command line.
The UART is configured according to the request, or to the specific constant baud rate or auto
baud rate after output "OK" response to the terminal. For example, AT+CBAUD=8 is equivalent
to AT+CBAUD=57600. Using AT+CBAUD with the <rate> value other than 9 or 0 disables the
auto baud rate detection feature.
Command Type
Set
Read
Test
The following table shows the +CBAUD parameters.
Example
AT+CBAUD=57600
or
AT+CBAUD=8
OK
3-132
Syntax
AT+CBAUD=<n>
AT+CBAUD=<rate>
AT+CBAUD?
AT+CBAUD=?
Table 3-84: +CBAUD Parameters
<Parameter>
<n> <rate>
0
Auto baud rate
1
600
2
1200
3
2400
4
4800
5
9600
6
19200
7
38400
8
57600
9
Auto baud rate
10
115200
11
300
12
230400
13
460800
The default value is 9.
//These commands have the same effect
G24-L AT Commands Reference Manual
Response/Action
OK
or:
ERROR
+CBAUD: <rate>
+CBAUD: (list of supported <n>s, list of
supported <rate>s)
Description