Command Type
Set
Read
The following table shows the S24 parameters.
<Parameter>
<value>
Example
ATS24? <enter>
000
OK
ATS24=5 <enter>
OK
ATS24? <enter>
005
OK
(If there are no radio and UART activities, the G24-L will enter sleep mode in 5 seconds)

S102, Set Delay Before Sending Data to the Terminal

This command sets the value of the delay before sending data to the terminal. Before receiving
data, the terminal connected to the G24-L will receive:
Terminal Wakeup signal (the Wakeup Out Line (pin #26) state will be active low).
A delay that is equal ATS102 value.
Data (GPRS, CSD, AT commands' echo and results, unsolicited reports).
April 15, 2008
Syntax
Response/Action
ATS24=[<value>]
OK
ATS24?
<value>
OK
Table 3-135: S24 Parameters
Number of seconds (0 <= n <= 255)
0
Disable Sleep mode
>0
Enable Sleep mode
The default value is 0.
G24-L AT Commands Reference Manual
Chapter 3: AT Commands Reference
Remarks
The Set command sets the amount of
time, in seconds, the G24-L should
wait before entering Sleep mode.
The Read command returns the current
value.
Description
3-203