Table 4-77 23 Ghz Etsi With 56 Mhz Channel Separation; Table 4-78 26 Ghz Etsi With 7 Mhz Channel Separation - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

User Guide: PTP 800 Licensed Ethernet Microwave

Table 4-77 23 GHz ETSI with 56 MHz channel separation

256
Modulation
QAM
0.91
Yes
Fixed/ref
Capacity
368.6
(Mbit/s)
Sensitivity
-63.2
(dBm)
ACM thresh
-58.1
out (dBm)
ACM thresh
-56.1
in (dBm)
Max tx
15
power
(dBm)
Min tx
7
power
(dBm)
Capacity, transmit power and sensitivity - 26 GHz ETSI

Table 4-78 26 GHz ETSI with 7 MHz channel separation

Modulation
Fixed/ref
Capacity
(Mbit/s)
Sensitivity
(dBm)
ACM thresh
out (dBm)
ACM thresh
in (dBm)
Max tx
power (dBm)
Min tx power
(dBm)
phn-1478_005v000
Apr 2010
256
128
QAM
QAM
0.80
0.82
Yes
Yes
347.1
303.5
-65.1
-67.8
-58.1
-64.5
-56.1
-63.2
15
17
7
7
128QAM
64QAM
0.76
0.82
Yes
Yes
34.4
30
-76.4
-78.8
-71.7
-74.2
-70.3
-72.9
17
17
7
7
64
32
QAM
QAM
0.82
0.84
Yes
No
255.2
202.7
-70.8
-
-67.3
-70.2
-66.1
-68.9
17
22
7
7
32QAM
16QAM
0.87
0.88
No
Yes
24.6
20
-
-83.7
-76.4
-79.6
-75.2
-78.3
22
22
7
7
Wireless operation
16
8PSK
QAM
0.80
0.79
Yes
No
152.4
115.8
-77.2
-
-74.2
-75.9
-73
-74.7
22
22
7
7
8PSK
QPSK
0.86
0.88
No
Yes
14.7
10
-
-90.4
-81.4
-
-80.1
-
22
25
7
7
QPSK
0.80
Yes
77.1
-83
-
-
25
7
4-55