Installing the IF and ground cables

Installing the IF and ground cables
Perform this task to install the IF cable connection from the ODU to the CMU, and
to provide grounding and lightning protection for the installation.
This task consists of three procedures:
x
Connecting the ODU to the top LPU
x
Installing and grounding the IF cable on a mast
x
Installing and grounding the IF cable at building entry
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
5-58
The IF and ground cable installation must meet the requirements defined
in
Grounding and lightning protection
To provide effective protection against lightning induced surges,
grounding cables must be installed without drip loops and pointing down
towards the ground. To install a cable ground kit at a grounding point,
follow the cable ground kit manufacturer's instructions.
To ensure that IF connections are not damaged by water ingress, all
outdoor IF connectors must be protected from the weather with self
amalgamating and vinyl tape.
Do not connect or disconnect the IF cable when the –48 V supply is
applied to the CMU.
Always ensure the lightning protection units are connected the correct
way round
(Figure
5-1).
on page 5-60.
on page 5-65.
on page 5-68.
on page 2-6.
Chapter 5 Installation
phn-1478_005v000
Apr 2010